6 Error description and removal
All rights reserved. The reproduction of this document, also partially, is allowed only with authorization by alpitronic s.r.l.
6. Error description and removal
Attention
Attention
Observe all hazard warnings in chapter 1.3
Check if circuit breakers are
switched on
Power-stack cannot be
turned on
The circuit breaker (-QB1,
-FB2) of the power-stack is
switched off
Turn on the circuit breaker
No communication to the
backend
No connection via Ethernet or
mobile network
Check connection of the Ethernet
network (-XF1) or/and antenna
(-TF1)
Boot the charging station in
diagnostics mode and use the
diagnostic tool for further fault
localization
Error in the configuration of the
charging station
Boot the charging station in
diagnostics mode and use the
diagnostic tool for further fault
localization
Table 18: Error description and troubleshooting