JUKI FX-1 - Replacing the Filter Element

JUKI FX-1
212 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
FX-1/FX-1R Maintenance Manual
9-2. Replacing the Filter Element
(1) Turn the filter element main unit 45° clockwise or counterclockwise to pull it out downward
while lowering the slide part.
(2) When replacing the filter element B on the air filter side, turn the resin part fixing the filter
element B counterclockwise to detach it.
(3) When replacing the filter element A on the mist separator side, turn the filter element A
counterclockwise to detach it.
(4) Reassemble the components in the reverse order of disassembly.
<CAUTION>
Before replacing the filter element, always close the knob of the finger valve.
The filter element must be replaced when it has been used for two years or when
pressure drop reaches 0.1 MPa (1kgf/cm
2
).
Mist separator
A
ir filte
r
PF901002000
PF901006000
Filter element A
Filter element B
Resin part
Slide part
9-2