Table 39: Details of a Virtual Chassis Member Switch
Details Example
Model number of the member switch EX3300
Assigned ID that applies to the enre Virtual
Chassis conguraon
ID 2
NOTE: If the member switch is not provisioned, the serial
number of the switch is displayed instead of its ID.
Role of the member switch Master
Possible roles are: Master, Backup, or Linecard
Status of the member switch Prsnt
Possible statuses are: Prsnt, NotPrsnt, Inacve, or Unprvsnd
The status of the member switch is displayed on the image of the switch. If the member switch appears
dimmed, it means the switch is not present, is inacve, or is not provisioned in the Virtual Chassis. If the
member switch does not appear dimmed, it means the switch is present and is acve.
Table 40 on page 186 describes the possible status of a member switch.
Table 40: Status of a Member Switch in a Virtual Chassis
If the member switch is It appears as It means the member switch
Present Prsnt Has established physical and logical connecons with Virtual Chassis
member switches.
Not present dimmed and
NotPrsnt
Has been disconnected from the exisng Virtual Chassis.
Inacve dimmed and
Inacve
Has established physical connecons, but is unable to establish logical
connecons.
186

Table of Contents