Feature Value
PTC testing current [A]
(according to EN 50342)
640
Tab. 39 Battery
Further information Depending on machine equipment, a higher capacity battery may be required. See chapter 2.7.2.
2.7 Options
2.7.1 Air treatment options
2.7.1.1 Option ea, ec
Tool lubricator
Name Temperature range [°F] Fluid volume [gal]
Special road breaker lubricant −13 ..... 122 2.64
Tab. 40 Road breaker lubricant recommendation
2.7.1.2 Option dc
Fresh air filter
Feature Value
Maximum working pressure [psig] 232
Minimum ambient temperature [°F] 34.7
Maximum ambient temperature [°F] 86
Tab. 41 Fresh air filter conditions
2.7.1.3 Air quality at the compressed air outlets
Interrelation between compressed air treatment and compressed air quality:
Air Treatment Compressed air quality
Option designation Components Characteristics Abbreviation
da ■ After-cooler
■
Cyclone separator
cool and condensate-
free
A
da + db ■ After-cooler
■ Cyclone separator
■ Heat exchanger
dry and warmed B
da + dd ■ After-cooler
■ Cyclone separator
■ Filter combination
dry and technically oil-
free
F
da + dd + db ■ After-cooler
■ Cyclone separator
■ Filter combination
■ Heat exchanger
technically oil-free and
warmed
G
2 Technical Data