Allow the machine to cool down.
Do not open the body while the machine is switched on.
Do not open or dismantle any valves.
Use only spare parts approved by KAESER for use in this machine.
Operate the machine only in technically sound condition.
Carry out regular inspections:
for visible damage and leakage,
of safety devices,
of the EMERGENCY STOP devices (if present),
of parts needing monitoring.
Pay particular attention to cleanliness during all maintenance and repair work. Cover compo‐
nents and openings with clean cloths, paper or tape to keep them clean.
Do not leave any loose components, tools or cleaning rags on or in the machine.
Components removed from the machine can still be dangerous.
Do not attempt to open or destroy any components taken from the machine.
Self-locking nuts removed for the installation must not be reused but replaced by new nuts, be‐
cause the non-positive safety is no longer ensured.
Use only suitable compressed air hoses.
Compressed air hoses must meet the following requirements:
they are of the right type and size for the highest permissible machine working pressure,
they are not damaged, worn or of reduced quality,
they have couplings and connections of the right type and size.
Wear protective gloves when connecting or disconnecting compressed air hoses.
Make sure compressed air hoses are de-pressurised before disconnecting from the machine.
Secure the open end of an air hose before applying air pressure. An unsecured hose may whip
and cause injury.
At working pressures>100 psi, compressed air hoses should be secured by a cable to their re‐
spective outlet valves.
Connect and operate only suitable air tools.
The air tools must meet the set output pressure of the machine.
Use a pressure reducer for air tools requiring a lower pressure.
Use compressed air tools only with the pressure appropriate for its purpose (tool working pres‐
sure).
3.5.2.4 De-commissioning, storage and disposal
Improper handling of old operating fluids and components represent a danger for the environment.
Drain off fluids and dispose of them according to environmental regulations.
These include, for example, fuel, engine oil and compressor cooling oil and engine coolant.
Dispose of the machine in accordance with local environmental regulations.
3.5.3 Organizational Measures
Designate personnel and their responsibilities.
3 Safety and Responsibility
3.5 Dangers
32
Operator Manual Screw Compressor
M100 No.: 9_6999 23 USE

Table of Contents