2.2.15 Option pa, pb
Instrument panel cover
Option Option code Available?
Instrument panel cover pa
Generator control box cover pb
Tab. 20 Instrument panel cover options
2.3 Machine (without options)
2.3.1 Sound pressure level
Sound pressure levels comply with the American EPA Standard.
Measurement distance: 23 ft
M100
Guaranteed sound pressure level [dB(A)] 76
Tab. 21 Sound pressure level
2.3.2 Tightening torques for screws
Recommended values for screws of property class 8.8
Thread M4 M5 M6 M8 M10 M12 M14 M16 M18 M20
Torque [lbf-in] 26.6 52.2 88.5 216.8 424.8 743.5 1177 1823 2611 3673
Tab. 22 Tightening torques for screws (property class 8.8, coefficient of friction µ = 0.12)
2.3.3 Ambient conditions
Positioning Limit value
Maximum altitude amsl* [ft] 3280
Minimum ambient temperature [°F] 14
Maximum ambient temperature [°F] 122
* Higher altitudes are permissible only after consultation with the manufacturer.
Tab. 23 Ambient conditions
2.3.4 Additional specifications
For specifications, according to the machine's operating license, such as:
■
dimensions,
■ track width,
■ footprint,
can be found in the dimensioned drawings in Chapter 13.3.
2 Technical Data
2.3 Machine (without options)
No.: 9_6999 23 USE
Operator Manual Screw Compressor
M100
9