DEVICE DATA OF THE 400 V DEVICES
The values for the respective unit size are listed in the following tables.
Frequency-dependent maximum current
Device size
21
Rated switching frequency
8 kHz
Output frequency f
out
/ Hz
0 1.5 3 6 10 25
Frequency-dependent maximum current @ fS
Basic Time Period = 62.5 µs (Parameter is22=0)
I
lim/%
2 kHz 180
180 180
180
180
180
4 kHz 180
180 180
180
180
180
8 kHz 133
158 175
180
180
180
16 kHz 55
71 83
99
110
133
Frequency-dependent maximum current @ fS
Basic Time Period = 71.4 µs (Parameter is22=1)
I
lim/%
1.75 kHz 180
180 180
180
180
180
3.5 kHz 180
180 180
180
180
180
7 kHz 150
175 180
180
180
180
14 kHz 71
89 101
118
132
159
Frequency-dependent maximum current @ fS
Basic Time Period = 83.3 µs (Parameter is22=2)
I
lim/%
1.5 kHz 180
180 180
180
180
180
3 kHz 180
180 180
180
180
180
6 kHz 167
180 180
180
180
180
12 kHz 87
108 120
138
155
180
Frequency-dependent maximum current @ fS
Basic Time Period = 100 µs (Parameter is22=3)
I
lim/%
1.25 kHz 180
180 180
180
180
180
2.5 kHz 180
180 180
180
180
180
5 kHz 180
180 180
180
180
180
10 kHz 110
133 147
168
180
180
Table 14: Frequency-dependent maximum current for unit size 21

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the KEB COMBIVERT F6 Series and is the answer not in the manual?

KEB COMBIVERT F6 Series Specifications

General IconGeneral
BrandKEB
ModelCOMBIVERT F6 Series
CategoryDC Drives
LanguageEnglish

Related product manuals