DEVICE DATA OF THE 400 V DEVICES
Device size
23
Rated switching frequency
4 kHz
Output frequency f
out
/ Hz
0 1.5 3 6 10 25
Frequency-dependent maximum current @ fS
Basic Time Period = 62.5 µs (Parameter is22=0)
I
lim/%
2 kHz 154
171 180
180
180
180
4 kHz 121
134 154
180
180
180
8 kHz 79
88 102
125
147
180
16 kHz 35
39 45
55
65
81
Frequency-dependent maximum current @ fS
Basic Time Period = 71.4 µs (Parameter is22=1)
I
lim/%
1.75 kHz 155
171 180
180
180
180
3.5 kHz 130
143 164
180
180
180
7 kHz 90
100 115
141
164
180
14 kHz 43
48 55
68
80
100
Frequency-dependent maximum current @ fS
Basic Time Period = 83.3 µs (Parameter is22=2)
I
lim/%
1.5 kHz 155
171 180
180
180
180
3 kHz 138
152 174
180
180
180
6 kHz 100
111 128
156
180
180
12 kHz 51
57 65
81
96
119
Frequency-dependent maximum current @ fS
Basic Time Period = 100 µs (Parameter is22=3)
I
lim/%
1.25 kHz 155
171 180
180
180
180
2.5 kHz 146
162 180
180
180
180
5 kHz 111
123 141
171
180
180
10 kHz 65
72 84
103
122
151
Table 17: Frequency-dependent maximum current for device size 23 (4 kHz)
Device size
23
Rated switching frequency
8 kHz
Output frequency f
out
/ Hz
0 1.5 3 6 10 25
Frequency-dependent maximum current @ fS
Basic Time Period = 62.5 µs (Parameter is22=0)
I
lim/%
2 kHz 180
180 180
180
180
180
4 kHz 173
180 180
180
180
180
8 kHz 120
133 153
180
180
180
16 kHz 58
64 75
93
110
138
Frequency-dependent maximum current @ fS
Basic Time Period = 71.4 µs (Parameter is22=1)
I
lim/%
1.75 kHz 180
180 180
180
180
180
3.5 kHz 180
180 180
180
180
180
7 kHz 133
147 169
180
180
180
14 kHz 70
77 90
111
132
164
Frequency-dependent maximum current @ fS
Basic Time Period = 83.3 µs (Parameter is22=2)
I
lim/%
1.5 kHz 180
180 180
180
180
180
3 kHz 180
180 180
180
180
180
6 kHz 147
162 180
180
180
180
12 kHz 81
90 105
130
153
180
Frequency-dependent maximum current @ fS
Basic Time Period = 100 µs (Parameter is22=3)
I
lim/%
1.25 kHz 180
180 180
180
180
180
2.5 kHz 180
180 180
180
180
180
5 kHz 160
176 180
180
180
180
10 kHz 101
111 129
159
180
180
Table 18: Frequency-dependent maximum current for device size 23 (8 kHz)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the KEB COMBIVERT F6 Series and is the answer not in the manual?

KEB COMBIVERT F6 Series Specifications

General IconGeneral
BrandKEB
ModelCOMBIVERT F6 Series
CategoryDC Drives
LanguageEnglish

Related product manuals