WATER-COOLED DEVICES
Special requirements for open and half-open cooling systems:
Requirement Description
Impurities Mechanical impurities in half-open cooling systems can be counteracted when ap-
propriatewaterltersareused.
Salt concentration The salt content can increase through evaporation at half-open systems. Thus the
water is more corrosive. Adding of fresh water and removing of process water
works against.
Algae and myxobacte-
ria
Algae and myxobacteria can arise caused by increased water temperature and
contactwithatmosphericoxygen.Thealgaeandmyxobacteriaclogtheltersand
obstructthewater-ow.Biocidecontainingadditivescanavoidthis.Especiallyat
longer OFF periods of the cooling circuit preventive maintenance is necessary.
Organic materials The contamination with organic materials must be kept as small as possible, be-
cause separate slime can be caused by this
Table 40: Special requirements for open and half-open cooling systems for water coolers:
Damages at the unit which are caused by clogged, corroded heat sinks or other
obvious operating errors, leads to the loss of the warranty claims.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the KEB COMBIVERT F6 Series and is the answer not in the manual?

KEB COMBIVERT F6 Series Specifications

General IconGeneral
BrandKEB
ModelCOMBIVERT F6 Series
CategoryDC Drives
LanguageEnglish

Related product manuals