38
DEVICE DATA OF THE 400 V DEVICES
Device size
22
Rated switching frequency
4 kHz
Output frequency f
out
/ Hz
0 1.5 3 6 10 25
Frequency-dependent maximum current @ fS
Basic Time Period = 62.5 µs (Parameter is22=0)
I
lim/%
2 kHz 180
180 180
180
180
180
4 kHz 157
177 180
180
180
180
8 kHz 104
124 137
155
173
180
16 kHz 43
56 64
77
86
104
Frequency-dependent maximum current @ fS
Basic Time Period = 71.4 µs (Parameter is22=1)
I
lim/%
1.75 kHz 180
180 180
180
180
180
3.5 kHz 168
180 180
180
180
180
7 kHz 118
137 151
172
180
180
14 kHz 56
70 79
93
104
124
Frequency-dependent maximum current @ fS
Basic Time Period = 83.3 µs (Parameter is22=2)
I
lim/%
1.5 kHz 180
180 180
180
180
180
3 kHz 179
180 180
180
180
180
6 kHz 131
150 166
180
180
180
12 kHz 68
84 94
108
121
144
Frequency-dependent maximum current @ fS
Basic Time Period = 100 µs (Parameter is22=3)
I
lim/%
1.25 kHz 180
180 180
180
180
180
2.5 kHz 180
180 180
180
180
180
5 kHz 144
163 180
180
180
180
10 kHz 86
104 115
132
147
175
Table 15: Frequency-dependent maximum current for device size 22
Device size
23
Rated switching frequency
2 kHz
Output frequency f
out
/ Hz
0 1.5 3 6 10 25
Frequency-dependent maximum current @ fS
Basic Time Period = 62.5 µs (Parameter is22=0)
I
lim/%
2 kHz 154
169 180
180
180
180
4 kHz 121
130 149
168
180
180
8 kHz 80
95 105
119
133
157
16 kHz 33
43 49
59
66
80
Frequency-dependent maximum current @ fS
Basic Time Period = 71.4 µs (Parameter is22=1)
I
lim/%
1.75 kHz 154
169 180
180
180
180
3.5 kHz 129
144 158
177
180
180
7 kHz 90
105 116
132
146
172
14 kHz 43
54 61
71
79
95
Frequency-dependent maximum current @ fS
Basic Time Period = 83.3 µs (Parameter is22=2)
I
lim/%
1.5 kHz 154
169 180
180
180
180
3 kHz 137
153 167
180
180
180
6 kHz 100
115 127
144
159
180
12 kHz 52
65 72
83
93
111
Frequency-dependent maximum current @ fS
Basic Time Period = 100 µs (Parameter is22=3)
I
lim/%
1.25 kHz 154
169 180
180
180
180
2.5 kHz 146
161 176
180
180
180
5 kHz 111
126 138
156
172
180
10 kHz 66
80 88
101
113
134
Table 16: Frequency-dependent maximum current for device size 23 (2 kHz)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the KEB COMBIVERT F6 Series and is the answer not in the manual?

KEB COMBIVERT F6 Series Specifications

General IconGeneral
BrandKEB
ModelCOMBIVERT F6 Series
CategoryDC Drives
LanguageEnglish

Related product manuals