4Powerstage
Chapter overview
Pictogram
Navigation ►Projecttree►Devicesetup►Powerstage
Brief description Thischapterdescribestheconfigurationoptionsforthepower
stage(powersupply,switchingfrequency,powerfailure
bridging).
Contents
4.1 Power stage settings 25
4.2 Power failure bridging 28
ID No.: 0842.26B.5-01Date: 09.2020
ServoOne- Device Help
25
4 Power stage
4.1Powerstagesettings
Image 4.1: “Power stage settings” screen AC device
The power stages of the Servo controller can be operated with different voltages and
switching frequencies. The list boxes in the screen are used to adapt the power
stage to the application conditions.
NOTE
l Anychangestoparametersmustbesavedinthedevice.
l Thesettingisonlyappliedonthedeviceafterapoweroff/on
cycle.
l Ifthepowerstageparametersarechanged,theratedcurrents,
overloadvaluesandbrakechopperthresholdsmayalsochange.