EasyManua.ls Logo

Keba ServoOne junior - Error 16: Speed Difference Error

Keba ServoOne junior
493 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
11.6.17Error16:Speeddifferenceerror
11.6.17.1Error16-1(emergencycode8400h)
Cause: Speedtrackingerrortoolarge
Suggested steps:
Check your parameter P744
Thecontrolsystemfailedto
trackthereferencevalue
l Pleasecheckiftheaxisisblocked.
l Trytoreduceaccelerationordeceleration.
l Ifreferencespeedishigherthanthemotor
ratedspeed,pleasecheckfieldweakening
settings.Infield-weakeningrange,the
availabletorquepercurrentisreduced.
Thespeedcontrolmightrun
away,mostlikelyduetoa
wrongencoderoffset.
l Pleasecheckthattheencoderoffsetisset
properly.
l Ifautocommutationisused,re-viewtheauto
commutationsettingandtestunderall
possibleconditions.
l Iftorquemodeisused,reducetorque,ensure
externalspeedlimitation,orincreasespeed
controlgainforstrongerlimitation.
ThisispossiblyanEMC
issue.Thisisverylikelyifthe
problemoccurswhen
switchingonmotorcontrol
and/orwhenconnectingDC
linkpowersupply.
l Pleasecheckthedevicecablingforproper
connection.
l Pleasecheckdevicegrounding,i.e.the
connectiontoametalbackplaneandcabinet
connectiontoearth.
l Checkmotorgroundingandmotorcable
length.
ID No.: 0842.26B.5-01Date: 09.2020
ServoOne- Device Help
376
11 Alarms & warnings
11.6.17.2Error16-2(emergencycode8400h)
Cause: Currentspeedabovemaximumspeedofmotor>120%
Suggested steps:
Check your parameter data set
Thecontrolsystemfailedto
trackthereferencevalue
l Pleasecheckiftheaxisisblocked.
l Trytoreduceaccelerationordeceleration.
l Ifreferencespeedishigherthanthemotor
ratedspeed,pleasecheckfieldweakening
settings.Infield-weakeningrange,the
availabletorquepercurrentisreduced.
Thespeedcontrolmightrun
away,mostlikelyduetoa
wrongencoderoffset.
l Pleasecheckthattheencoderoffsetisset
properly.
l Ifautocommutationisused,re-viewtheauto
commutationsettingandtestunderall
possibleconditions.
l Iftorquemodeisused,reducetorque,ensure
externalspeedlimitation,orincreasespeed
controlgainforstrongerlimitation.
ThisispossiblyanEMC
issue.Thisisverylikelyifthe
problemoccurswhen
switchingonmotorcontrol
and/orwhenconnectingDC
linkpowersupply.
l Pleasecheckthedevicecablingforproper
connection.
l Pleasecheckdevicegrounding,i.e.the
connectiontoametalbackplaneandcabinet
connectiontoearth.
l Checkmotorgroundingandmotorcable
length.

Table of Contents

Other manuals for Keba ServoOne junior

Related product manuals