EasyManua.ls Logo

Keba ServoOne junior - Error Reactions

Keba ServoOne junior
493 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Immediately after an error occurs, it will be shown in a window. After closing the
window by clicking on “Quit error” or “Later,” you can view the current error and the
20 most recent errors (see Section "Alarms and warnings (Details)" on page 330).
ID No.: 0842.26B.5-01Date: 09.2020
ServoOne- Device Help
339
11 Alarms & warnings
11.5Errorreactions
l P 30 - ErrorReactionsisusedtodefinehowtheServocontrollerwill
respondintheeventofanerror.Theseresponsesaredefinedindividuallyfor
62differenterrorscenarios.Aselectionofuptoninedifferentresponseswill
beavailable(seeSection"Errorreactions"onpage339).
l P 38[0] - ERR_Specific2OptCodecanbeusedtodefineanadditionalerror
responseiftheServocontrollerfeaturesanoptionalfunctionpackage.
Error reaction Function
Ignore(0)
Ignoreerror
Exception:FortheHWlimitswitch,inwhichcasea
warningwillbegenerated(P 34bit29orbit30)
Specific1(1)
Theerrorwillbereported;theresponsewillbe
carriedoutbytheintegratedPLC(V2.0andhigher)
Exception:FortheHWlimitswitch,inwhichcasea
warningwillbegenerated(P 34bit29orbit30)and
therewillbeaSTOPrequest(decelerationwithramp
dependingontheSTOPoptioncode,withoutany
changetotheDRIVECOMsystemstate).Atstandstill
therelevantdirectionisblockedaslongasthelimit
switchisactive.
Specific2(2)
Theerrorwillbereported;theresponsewillbe
carriedoutbyanexternalcontroller
Table 11.6: Error reactions