11.6.28.3Error28-3(emergencycode7307h)
Cause: Channel 3 cyclic, Np (distance coded): error, calculated 'delta' is out of range
Suggested steps:
Please check the wiring of the encoder
Encoderchannel,cyclic
evaluation
l Errorduringthecyclicevaluationofan
encoderchannel3.
l Inanycaselookatinitoutputsinthemessage
windowoftheDriveManager.
l Themostcommoncauseoferroristhewiring
totheencoder.
ID No.: 0842.26B.5-01Date: 09.2020
ServoOne- Device Help
413
11 Alarms & warnings
11.6.29Error30:Controlinitializationerror
11.6.29.1Error30-1(emergencycode5300h)
Cause: Initializationerroranalogueinput
Suggested steps:
Check calibration of analog inputs
Thisissueisprobably
causedbyanunsuitable
parametersetting.
l Saveyourparametersetforalaterrestore.
l See'historyofparameterchanges'andundo
thelatestchanges.
l Pleasecheckyourparametersetfor
implausiblesettings.
l Pleasesetdevicetofactorysetting,restart,and
seeiftheerroroccursagain.
l Whenreportingthiserrortoyourservice
partner,pleaseincludeyourdevice's
parametersetting.