EasyManua.ls Logo

Keba ServoOne junior - Page 381

Keba ServoOne junior
493 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
11.6.20.3Error19-3(emergencycode5400h)
Cause: PST:InvalidEEPROMdata
Suggested steps:
Call your service provider.
Thisisprobablyasoftware
issue.
l Pleasetrytoswitchtoadifferentversionof
devicefirmware.
l Saveyourdatasetandresettheaxismoduleto
factorysetting.Seeiftheerrorpersists,orifit
comeswithactivatingacertainfeature.
Thisispossiblyahardware
issue
Ifothermeasuresfailtosolvetheproblem,please
replacetheservocontroller.
11.6.20.4Error19-4(emergencycode5400h)
Cause: PST:CRCerror
Suggested steps:
Call your service provider.
Thisisprobablyasoftware
issue.
l Pleasetrytoswitchtoadifferentversionof
devicefirmware.
l Saveyourdatasetandresettheaxismoduleto
factorysetting.Seeiftheerrorpersists,orifit
comeswithactivatingacertainfeature.
Thisispossiblyahardware
issue
Ifothermeasuresfailtosolvetheproblem,please
replacetheservocontroller.
ID No.: 0842.26B.5-01Date: 09.2020
ServoOne- Device Help
381
11 Alarms & warnings
11.6.20.5Error19-5(emergencycode5400h)
Cause: PST:Errorreadingpowerstagedata
Suggested steps:
Call your service provider.
Thisisprobablyasoftware
issue.
l Pleasetrytoswitchtoadifferentversionof
devicefirmware.
l Saveyourdatasetandresettheaxismoduleto
factorysetting.Seeiftheerrorpersists,orifit
comeswithactivatingacertainfeature.
Thisispossiblyahardware
issue
Ifothermeasuresfailtosolvetheproblem,please
replacetheservocontroller.
11.6.20.6Error19-6(emergencycode5400h)
Cause: PST:Errorwritingpowerstagedata
Suggested steps:
Call your service provider.
Thisisprobablyasoftware
issue.
l Pleasetrytoswitchtoadifferentversionof
devicefirmware.
l Saveyourdatasetandresettheaxismoduleto
factorysetting.Seeiftheerrorpersists,orifit
comeswithactivatingacertainfeature.
Thisispossiblyahardware
issue
Ifothermeasuresfailtosolvetheproblem,please
replacetheservocontroller.

Table of Contents

Other manuals for Keba ServoOne junior

Related product manuals