11.6.23.8Error22-8(emergencycode7305h)
Cause: Channel 1 Initialization, EndDat 2.1: CRC error, position data from encoder
Suggested steps:
The transmission is probably disturbed. Please check the wiring to the encoder.
Initializationencoder
channel1
l Errorduringtheinitializationroutinesof
encoderchannel1.
l Inanycaselookatinitoutputsinthemessage
windowoftheDriveManager.
l Themostcommoncauseoferroristhewiring
totheencoder.
11.6.23.9Error22-9(emergencycode7305h)
Cause: Channel 1 Initialization, EndDat 2.1: CRC error, parameter data from
encoder
Suggested steps:
The transmission is probably disturbed. Please check the wiring to the encoder.
Initializationencoder
channel1
l Errorduringtheinitializationroutinesof
encoderchannel1.
l Inanycaselookatinitoutputsinthemessage
windowoftheDriveManager.
l Themostcommoncauseoferroristhewiring
totheencoder.
ID No.: 0842.26B.5-01Date: 09.2020
ServoOne- Device Help
395
11 Alarms & warnings
11.6.23.10Error22-10(emergencycode7305h)
Cause: Channel 1 Initialization, EndDat 2.1: not allowed write operation to write
protected cells or protection cells of the encoder
Suggested steps:
No further information available. Please contact your service provider.
Initializationencoder
channel
l Thisisprobablyasoftwareproblem!
l Inanycaselookatinitoutputsinthemessage
windowoftheDriveManager.
11.6.23.11Error22-15(emergencycode7305h)
Cause: Channel 1 Initialization, SSI: 'MultiTurn' from parameter (543) ENC_CH1_
MultiT
Suggested steps:
Change the input of the multiturn bits of the parameter.
Initializationencoder
channel
l Thisisprobablyaproblemofthe
parameterization!
l Inanycaselookatinitoutputsinthemessage
windowoftheDriveManager.