5 Pulse Mode Operation (Model 2430 only)
Overview .................................................................................... 5-2
Pulse characteristics .................................................................... 5-3
Pulse width .......................................................................... 5-4
Signal measurement ..................................................... 5-4
Overhead time .............................................................. 5-4
Pulse width delay ......................................................... 5-5
Output off-time .................................................................... 5-5
Reference and zero measurements ............................... 5-5
Overhead time .............................................................. 5-5
Pulse delay ................................................................... 5-6
Pulse duty cycle ................................................................... 5-6
Fast pulse output .................................................................. 5-6
Auto zero ...................................................................... 5-7
Pulse-only ..................................................................... 5-8
Pulse jitter ............................................................................ 5-8
Pulse energy limitations (10A range) ......................................... 5-9
Pulse Mode configuration ......................................................... 5-10
Front panel Pulse Mode configuration .............................. 5-10
Select Pulse Mode, and set pulse width
and pulse delay ....................................................... 5-10
Set pulse measurement speed ..................................... 5-10
Set pulse count ........................................................... 5-10
Disable/enable auto zero ............................................ 5-11
Remote command Pulse Mode configuration ................... 5-11
Basic Pulse Mode operation ..................................................... 5-12
Front panel pulse-measure procedure ............................... 5-12
Step 1: Select Pulse Mode, and set pulse width
and pulse delay. ...................................................... 5-12
Step 2: Set pulse measurement speed. ....................... 5-12
Step 3: Set pulse count. .............................................. 5-12
Step 4: Select source. ................................................. 5-13
Step 5: Set pulse level and compliance limit. ............. 5-13
Step 6: Select measurement function and range. ....... 5-13
Step 7: Turn output on. ............................................... 5-14
Pulse-ohms measurements ................................................ 5-14
Auto and Manual pulse-ohms measurements ............ 5-14
Offset-compensated pulse-ohms measurements ........ 5-14
Remote command pulse-measure operation ..................... 5-15
Basic pulse commands ............................................... 5-15
Ignored settings and invalid commands ..................... 5-15
Pulse-measure programming example ....................... 5-16
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com