EasyManua.ls Logo

Keysight Technologies E3646A - Page 199

Keysight Technologies E3646A
260 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Characteristics and Specifications 7
Supplemental Characteristics
E364xA User’s and Service Guide 175
Overvoltage protection accuracy
±(% of output + offset)
<0.5% + 0.5 V
Overvoltage protection response time <1.5 ms when the trip voltage is 3 V
<10 ms when the trip voltage is <3 V
Input power option
(selectable via two switches on the PC board)
115 Vac ±10%, 47 Hz to 63 Hz (standard)
230 Vac ±10%, 47 Hz to 63 Hz (option 0E3)
100 Vac ±10%, 47 Hz to 63 Hz (option 0E9)
Maximum input power 210 VA 210 VA 400 VA 330 VA
[1] Maximum change in the output or readback per °C after a 30-minute warm-up.
[2] Following a 30-minute warm-up, with the output in the ON state according to the operating mode (CC with load or CV), and
with a change in the output over 8 hours under constant load, line, and ambient temperature.
[3] During turn-on or turn-off of the AC power, if the output control is set to less than 1 V.
Table 7 - 3 Supplemental characteristics (continued)
Parameter E3646A E3647A E3648A E3649A

Table of Contents

Related product manuals