164 Keysight InfiniiVision 3000 X-Series Oscilloscopes User's Guide
10 Triggers
The following table lists the line (or count) numbers per field for each video
standard.
The following table lists the line numbers for each EDTV/HDTV video standard
(available with the extended video triggering license).
Video Triggering
Examples
The following are exercises to familiarize you with video triggering. These exercises
use the NTSC video standard.
• "To trigger on a specific line of video" on page 165
• "To trigger on all sync pulses" on page 166
• "To trigger on a specific field of the video signal" on page 167
• "To trigger on all fields of the video signal" on page 168
• "To trigger on odd or even fields" on page 169
To set up Generic video triggers
When Generic (available with the extended video triggering license) is selected as
the Video trigger Standard, you can trigger on custom bi-level and tri-level sync
video standards. The Video Trigger Menu changes as follows.
Video standard Field 1 Field 2 Alt Field
NTSC 1 to 263 1 to 262 1 to 262
PAL 1 to 313 314 to 625 1 to 312
PAL-M 1 to 263 264 to 525 1 to 262
SECAM 1 to 313 314 to 625 1 to 312
EDTV 480p/60 1 to 525
EDTV 567p/50 1 to 625
HDTV 720p/50, 720p/60 1 to 750
HDTV 1080p/24, 1080p/25, 1080p/30,
1080p/50, 1080p/60
1 to 1125
HDTV 1080i/50, 1080i/60 1 to 1125