166 Keysight InfiniiVision 3000 X-Series Oscilloscopes User's Guide
10 Triggers
4 Press the Mode softkey and select the TV field of the line you want to trigger on.
You can choose Line:Field1, Line:Field2, or Line:Alternate.
5 Press the Line # softkey and select the number of the line you want to examine.
To trigger on all sync pulses
To quickly find maximum video levels, you could trigger on all sync pulses. When
All Lines is selected as the Video trigger mode, the oscilloscope will trigger on all
horizontal sync pulses.
1 Press the [Trigger] key.
2 In the Trigger Menu, press the Trigger softkey; then, turn the Entry knob to
select Video.
NOTE
Alternate Triggering
If Line:Alternate is selected, the oscilloscope will alternately trigger on the selected line
number in Field 1 and Field 2. This is a quick way to compare the Field 1 VITS and Field 2 VITS
or to check for the correct insertion of the half line at the end of Field 1.
Figure 27 Example: Triggering on Line 136

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keysight Technologies InfiniiVision MSO-X 3014A and is the answer not in the manual?

Keysight Technologies InfiniiVision MSO-X 3014A Specifications

General IconGeneral
BrandKeysight Technologies
ModelInfiniiVision MSO-X 3014A
CategoryTest Equipment
LanguageEnglish

Related product manuals