7.9 Interpolated Position Mode (ip) (DS402)
7.9.1 General information
The interpolated position mode is implemented in a simple, straightforward way. Single position setpoints must
be transmitted in the interpolation time period and are taken over on every defined SYNC - telegram sent. A linear
interpolation is used between the setpoints. Examples can be found from page => p. 151.
7.9.1.1 Objects defined in this section
Index Object Name Type Access
60C0h VAR Interpolation sub mode select INTEGER16 R/W
60C1h ARRAY Interpolation data record INTEGER32 R/W
60C2h RECORD Interpolation time period Interpolation time period R/W
60C4h RECORD Interpolation data configuration record Interpolation data con-
figuration record
R/W
7.9.1.2 Objects defined in other sections
7.9.2 Object description
7.9.2.1 Object 60C0h: Interpolation sub mode select
In the AKD, both linear interpolation between position setpoints and Cubic polynomial interpolation between posi-
tion/velocity/time setpoints are supported.
Index 60C0h
Name Interpolation sub mode select
Object code VAR
Data type INTEGER16
Category optional
Access R/W
PDO mapping not possible
Value range -2, -1, 0
Default value 0
Value description
Value(dec-
imal)
Description
0 Linear interpolation with a constant time.
-1 Reserved.
-2 Cubic polynomial interpolation, which is also known as position, velocity, and time (PVT) inter-
polation.
AKD CANopen | 7 CANopen Drive Profile
Kollmorgen | November 2012 105

Table of Contents

Other manuals for Kollmorgen AKD

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kollmorgen AKD and is the answer not in the manual?

Kollmorgen AKD Specifications

General IconGeneral
Control ModesTorque, Velocity, Position
Communication InterfacesEtherCAT, CANopen
Feedback OptionsResolver
SafetySTO (Safe Torque Off), SS1 (Safe Stop 1)
Protection FeaturesOvercurrent, Overvoltage, Undervoltage, Overtemperature
Operating Temperature Range0°C to 55°C
Humidity5% to 95% non-condensing

Related product manuals