AKD CANopen | 6 CANopen Communication Profile
6.3.1.2 Signed Integer
Data in the basic data type INTEGERn define both positive and negative integers.
The value range is from -2
n-1
-1 to 2
n-1
-1. The bit sequence b = b
0
to b
n-1
defines the value
INTEGERn(b) = b
n-2
2
n-2
+ to + b
1
2
1
+ b
0
2
0
with b
n-1
= 0
Negative numbers are represented as 2’s complement, which means:
INTEGERn(b) = - INTEGERn(b) - 1 with b
n-1
= 1
Example: the value -266 = FEF6h is transmitted in the data type INTEGER16, in the form of two octets (1
st
octet
= F6h, 2
nd
octet = FEh).
Transmission syntax for the data type INTEGERn
Octet number 1. 2. 3. 4.
INTEGER8 b
7
to b
0
INTEGER16 b
7
to b
0
b
15
to b
8
INTEGER24 b
7
to b
0
b
15
to b
8
b
23
to b
16
INTEGER32 b
7
to b
0
b
15
to b
8
b
23
to b
16
b
31
to b
24
INTEGER40 b
7
to b
0
b
15
to b
8
b
23
to b
16
b
31
to b
24
INTEGER48 b
7
to b
0
b
15
to b
8
b
23
to b
16
b
31
to b
24
INTEGER56 b
7
to b
0
b
15
to b
8
b
23
to b
16
b
31
to b
24
INTEGER64 b
7
to b
0
b
15
to b
8
b
23
to b
16
b
31
to b
24
Octet number 5. 6. 7. 8.
INTEGER8
INTEGER16
INTEGER24
INTEGER32
INTEGER40 b
39
to b
32
INTEGER48 b
39
to b
32
b
47
to b
40
INTEGER56 b
39
to b
32
b
47
to b
40
b
55
to b
48
INTEGER64 b
39
to b
32
b
47
to b
40
b
55
to b
48
b
63
to b
56
6.3.2 Mixed data types
Mixed data types combine basic data types (INTEGERn, UNSIGNEDn, REAL). Two types of mixed data are dis-
tinguished:
l STRUCT: This data type is composed of elements with different data types.
l ARRAY: This data type is composed of elements of the same data type.
30 Kollmorgen | November 2012

Table of Contents

Other manuals for Kollmorgen AKD

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kollmorgen AKD and is the answer not in the manual?

Kollmorgen AKD Specifications

General IconGeneral
Control ModesTorque, Velocity, Position
Communication InterfacesEtherCAT, CANopen
Feedback OptionsResolver
SafetySTO (Safe Torque Off), SS1 (Safe Stop 1)
Protection FeaturesOvercurrent, Overvoltage, Undervoltage, Overtemperature
Operating Temperature Range0°C to 55°C
Humidity5% to 95% non-condensing

Related product manuals