UsingtheIntegratedManagementModuleII(IMM2)
TheIntegratedManagementModuleII(IMM2)isasecondgenerationofthefunctionsthatwereformerly
providedbythebaseboardmanagementcontrollerhardware.Itcombinesserviceprocessorfunctions,video
controller,andremotepresencefunctioninasinglechip.
TheIMM2supportsthefollowingbasicsystems-managementfeatures:
Alerts(in-bandandout-of-bandalerting,PETtraps-IPMIstyle,SNMP,e-mail).
AutoBootFailureRecovery(ABR).
Automaticmicroprocessordisableonfailureandrestartinatwo-microprocessorconfigurationwhenone
microprocessorsignalsaninternalerror.Whenoneofthemicroprocessorsfail,theserverwilldisablethe
failingmicroprocessorandrestartwiththeothermicroprocessor.
AutomaticServerRestart(ASR)whenPOSTisnotcompleteortheoperatingsystemhangsandthe
operatingsystemwatchdogtimertimes-out.TheIMM2mightbeconfiguredtowatchfortheoperating
systemwatchdogtimerandrebootthesystemafteratimeout,iftheASRfeatureisenabled.Otherwise,
theIMM2allowstheadministratortogenerateanonmaskableinterrupt(NMI)bypressinganNMIbutton
onthelightpathdiagnosticspanelforanoperating-systemmemorydump.ASRissupportedbyIPMI.
Avirtualmediakey,whichenablesremotepresencesupport(remotevideo,remotekeyboard/mouse,
andremotestorage).
Bootsequencemanipulation.
Command-lineinterface.
Configurationsaveandrestore.
DIMMerrorassistance.TheUnifiedExtensibleFirmwareInterface(UEFI)disablesafailingDIMMthat
isdetectedduringPOST,andtheIMM2lightstheassociatedsystemerrorLEDandthefailingDIMM
errorLED.
Environmentalmonitorwithfanspeedcontrolfortemperature,voltages,fanfailure,powersupplyfailure,
andpowerbackplanefailure.
IntelligentPlatformManagementInterface(IPMI)SpecificationV2.0andIntelligentPlatformManagement
Bus(IPMB)support.
Invalidsystemconfiguration(CONFIG)LEDsupport.
LightpathdiagnosticsLEDsindicatorstoreporterrorsthatoccurwithfans,powersupplies,
microprocessor,harddiskdrives,andsystemerrors.
Localfirmwarecodeflashupdate
Nonmaskableinterrupt(NMI)detectionandreporting.
Operating-systemfailurebluescreencapture.
PCIconfigurationdata.
Power/resetcontrol(power-on,hardandsoftshutdown,hardandsoftreset,schedulepowercontrol).
Querypower-supplyinputpower.
ROM-basedIMM2firmwareflashupdates.
SerialoverLAN(SOL).
Serialportredirectionovertelnetorssh.
SMIhandling
Systemeventlog(SEL)-userreadableeventlog.
TheIMM2alsoprovidesthefollowingremoteservermanagementcapabilitiesthroughtheipmitool,a
managementutilityprogram:
96LenovoSystemx3250M5InstallationandServiceGuide