Handlingstatic-sensitivedevices
Usethisinformationtohandlestatic-sensitivedevices.
Attention:Staticelectricitycandamagetheserverandotherelectronicdevices.Toavoiddamage,keep
static-sensitivedevicesintheirstatic-protectivepackagesuntilyouarereadytoinstallthem.
Toreducethepossibilityofdamagefromelectrostaticdischarge,observethefollowingprecautions:
Limityourmovement.Movementcancausestaticelectricitytobuilduparoundyou.
Theuseofagroundingsystemisrecommended.Forexample,wearanelectrostatic-dischargewrist
strap,ifoneisavailable.Alwaysuseanelectrostatic-dischargewriststraporothergroundingsystem
whenworkinginsidetheserverwiththepoweron.
Handlethedevicecarefully,holdingitbyitsedgesoritsframe.
Donottouchsolderjoints,pins,orexposedcircuitry.
Donotleavethedevicewhereotherscanhandleanddamageit.
Whilethedeviceisstillinitsstatic-protectivepackage,touchittoanunpaintedmetalsurfaceonthe
outsideoftheserverforatleast2seconds.Thisdrainsstaticelectricityfromthepackageandfrom
yourbody.
Removethedevicefromitspackageandinstallitdirectlyintotheserverwithoutsettingdownthedevice.
Ifitisnecessarytosetdownthedevice,putitbackintoitsstatic-protectivepackage.Donotplacethe
deviceontheservercoveroronametalsurface.
Takeadditionalcarewhenhandlingdevicesduringcoldweather.Heatingreducesindoorhumidity
andincreasesstaticelectricity.
Removingthecover
Usethisinformationtoremovethecover.
Readthesafetyinformationin“Safety”onpagevand“Installationguidelines”onpage31.
Ifyouarereplacingaservercomponentorinstallinganoptionaldeviceintheserver,youneedtoslidethe
serveroutfromtherackenclosure,turnofftheserverandperipheraldevices,anddisconnectthepower
cordsandallexternalcables.
Toremovetheservercover,completethefollowingsteps.
Step1.Iftheserverhasbeeninstalledinarack,slidetheserveroutfromtherackenclosure.Refertothe
RackInstallationInstructionsformoreinformationoninstallingorremovingtheserverfromtherack.
Step2.Puttheserveronaworkingareabeforeyouremoveanyservercomponentsorpartsfromtheserver.
Step3.Putyourthumbsonthebluetabs(cover-releasebuttons).Pressonthebluetaborbuttonontheleft
andslidethecovertowardtherearoftheserveruntilthecoverhasdisengagedfromthechassis.
Chapter2.Installingoptionaldevices33