Maximumpower(watts):
SeePowerSupply.
Idlestatepower(watts):
84
Sleepmodepower(watts):
Notapplicableforservers.
Offmodepower(watts):
12
Noiselevels(thedeclaredA-weighedsoundpowerlevelofthecomputer):
SeeAcousticalnoiseemissions.
Testvoltageandfrequency:
230V/50Hzor60Hz
Totalharmonicdistortionoftheelectricitysupplysystem:
Themaximumharmoniccontentoftheinputvoltagewaveformwillbeequalorlessthan2%.The
qualificationiscompliantwithEN61000-3-2.
Informationanddocumentationontheinstrumentationset-upandcircuitsusedforelectricaltesting:
ENERGYSTARTestMethodforComputerServers;ECOVAGeneralizedTestProtocolforCalculating
theEnergyEfficiencyofInternalAc-DcandDc-DcPowerSupplies.
Measurementmethodologyusedtodetermineinformationinthisdocument:
ENERGYSTARServersVersion2.0ProgramRequirements;ECOVAGeneralizedTestProtocolfor
CalculatingtheEnergyEfficiencyofInternalAc-DcandDc-DcPowerSupplies.
Railandsupportedrackcabinetspecifications
OptionnameSystemx3250M52MBRSlide
OptionpartnumberN/A(defaultforSystemx3250M5servers)
Supportedrackcabinettype
Four-postIBMandLenovostandardrackcabinet,
complyingwiththeInternationalElectrotechnical
Commission(IEC)standard
Railtype
Half-outsliderail(friction),toollessinstallation
Serviceonrack
No
Mountingholes
Squareorround
Thicknessofmountingflanges
2mm(0.08inch)–4mm(0.16inch)
Distancebetweenfrontandrearmountingflanges
595mm(23.43inches)–789.7mm(31.09inches)
Cablemanagementarmsupport
No
Raillength(measuredwhenmountedontherack
cabinet,startingfromthefrontsurfaceofthefront
mountingflangetotherearmostpointoftherail)
798mm(31.42inches)
Note:Theoptionpartnumbersmightchange.
Whatyourserveroffers
Theserverusesthefollowingfeaturesandtechnologies.
•DynamicSystemAnalysis(DSA)
10LenovoSystemx3250M5InstallationandServiceGuide