Readthesafetyinformationin“Safety”onpagevand“Installationguidelines”onpage31.
Ifyouareinstallinganoptionaldeviceintheserver,youneedtoslidetheserveroutfromtherackenclosure,
turnofftheserverandperipheraldevices,anddisconnectthepowercordsandallexternalcables.
Note:Forbrevity,inthisdocumentationtheLenovoServeRAIDSAS/SATAcontrollerisoftenreferredtoas
theSAS/SATAadapterortheServeRAIDadapter.
ToinstallanoptionalServeRAIDSAS/SATAcontrollermemorymodule,completethefollowingsteps.
Step1.Removethecover(see“Removingthecover”onpage33).
Step2.RemovethePCIriser-cardassembly(see“RemovingthePCIriser-cardassembly”onpage163).
Step3.RemovetheServeRAIDSAS/SATAcontrollerifnecessary(“RemovinganLenovoServeRAID
SAS/SATAcontroller”onpage187).
Step4.Touchthestatic-protectivepackagethatcontainsthememorycardtoanyunpaintedmetalsurface
ontheserver;then,removethememorycardfromthepackage.
Step5.AlignthememorymodulewiththeconnectorontheServeRAIDSAS/SATAcontrollerandpush
itintotheconnectoruntilitisfirmlyseated.
Figure61.ServeRAIDSAS/SATAcontrollermemorymoduleinstallation
Step6.ReinstalltheServeRAIDSAS/SATAcontroller(“InstallinganLenovoServeRAIDSAS/SATA
controller”onpage61).
Step7.ReinstallthePCIriser-cardassembly(see“ReplacingthePCIriser-cardassembly”onpage78).
Ifyouhaveotherdevicestoinstall,dosonow.Otherwise,goto“Completingtheinstallation”onpage78.
InstallingaRAIDadapterbatteryorflashpowermodule
UsethisinformationtoinstallaRAIDadapterbatteryorflashpowermoduleintheserver.
WhenyouinstallanyRAIDadapterthatcomeswithbatteriesorflashpowermodules,itissometimes
necessarytoinstallthebatteriesorflashpowermodulesinanotherlocationintheservertopreventthe
batteriesorflashpowermodulesfromoverheating.Dependingonyourservermodel,abatterymustbe
installedremotelyneartheopticaldrivecageorthebackplane.
Note:RAIDadapterbatteryorflashpowermoduleisonlysupportedinthe2.5-inchmodels.
68LenovoSystemx3250M5InstallationandServiceGuide