Automaticallynotifysupport
No
AlertCategory
Critical-Temperature
SNMPTrapID
0
CIMInformation
Prefix:PLATID:0147
UserResponse
Noaction;informationonly.
IMMEventsthatautomaticallynotifySupport
YoucanconfiguretheIBMFlexSystemManagerortheCMMtoautomaticallynotifySupport(alsoknownas
callhome)ifcertaintypesoferrorsareencountered.Ifyouhaveconfiguredthisfunction,seethetablefor
alistofeventsthatautomaticallynotifySupport.
Table37.EventsthatautomaticallynotifySupport
EventIDMessageString
Automatically
NotifySupport
40000086-00000000
TestCallHomeGeneratedbyuser[arg1].
Yes
40000087-00000000
ManualCallHomebyuser[arg1]:[arg2].
Yes
80010202-0701ffff
Numericsensor[NumericSensorElementName]goinglow
(lowercritical)hasasserted.
Yes
80010902-0701ffff
Numericsensor[NumericSensorElementName]going
high(uppercritical)hasasserted.
Yes
806f0021-2201ffff
Faultinslot[PhysicalConnectorSystemElementName]on
system[ComputerSystemElementName].(NoOpROM
Space)
Yes
806f0021-2582ffff
Faultinslot[PhysicalConnectorSystemElementName]on
system[ComputerSystemElementName].(AllPCIError)
Yes
806f0021-3001ffff
Faultinslot[PhysicalConnectorSystemElementName]on
system[ComputerSystemElementName].(PCI1)
Yes
806f0021-3002ffff
Faultinslot[PhysicalConnectorSystemElementName]on
system[ComputerSystemElementName].(PCI2)
Yes
806f0108-0a01ffff
[PowerSupplyElementName]hasFailed.(PowerSupply1)
Yes
806f0108-0a02ffff
[PowerSupplyElementName]hasFailed.(PowerSupply2)
Yes
806f010c-2001ffffUncorrectableerrordetectedfor
[PhysicalMemoryElementName]onSubsystem
[MemoryElementName].(DIMM1)
Yes
806f010c-2002ffffUncorrectableerrordetectedfor
[PhysicalMemoryElementName]onSubsystem
[MemoryElementName].(DIMM2)
Yes
806f010c-2003ffffUncorrectableerrordetectedfor
[PhysicalMemoryElementName]onSubsystem
[MemoryElementName].(DIMM3)
Yes
AppendixA.IntegratedManagementModuleII(IMM2)errormessages529