Hazardousvoltage,current,andenergylevelsarepresentinsideanycomponentthathasthislabel
attached.Therearenoserviceablepartsinsidethesecomponents.Ifyoususpectaproblemwith
oneoftheseparts,contactaservicetechnician.
Readthesafetyinformationin“Safety”onpagev
and“Installationguidelines”onpage31.
Toreplaceorinstallahot-swappowersupply,completethefollowingsteps.
Step1.Slidethehot-swappowersupplyintothebayuntilthereleaselatchclicksintoplace.
Important:Duringnormaloperation,eachpower-supplybaymustcontaineitherapowersupply
orpower-supplyfillerpanelforpropercooling.
Figure149.Hot-swappowersupplyinstallation
Step2.Connectoneendofthepowercordforthenewpowersupplyintotheacconnectorontheback
ofthepowersupply;then,connecttheotherendofthepowercordintoaproperlygrounded
electricaloutlet.
Step3.Iftheserveristurnedoff,turnontheserver.
Step4.MakesurethattheacpowerLEDonthepowersupplyislit,indicatingthatthepowersupplyis
operatingcorrectly.Iftheserveristurnedon,makesurethatthedcpowerLEDonthepower
supplyislitalso.
RemovingthePCIriser-cardbracketfromthePCIriser-cardassembly
UsethisinformationtoremovethePCIriser-cardbracketfromthePCIriser-cardassembly.
Readthesafetyinformationin“Safety”onpagevand“Installationguidelines”onpage31.
Ifyouarereplacingaservercomponentintheserver,youneedtoslidetheserveroutfromtherack
enclosure,turnofftheserverandperipheraldevices,anddisconnectthepowercordsandallexternalcables.