2.Iftheerrorisnotreportedonthesubsequentboot,noadditionalrecoveryactionisrequired.
3.Iftheerrorpersists,continuebootingsystemandreflashUEFIimage.
4.(Trainedservicetechnicianonly)Replacethesystemboard.
•S.3818007[S.3818007]Thefirmwareimagecapsulesforbothflashbankscouldnotbeverified.
Explanation:CRTMimagecapsulecouldnotbeverified
Severity
Error
UserResponse
Completethefollowingsteps:
1.Ifsystemfailedtobootsuccessfully,DCcyclesystem.
2.IfsystembootstoF1steup,flashUEFIimageandresetbanktoprimary(ifrequired).Ifsystem
bootswithouterror,recoveryiscompleteandnoadditionalactionisrequired.
3.Ifsystemfailstoboot,orifflashattemptfails,(trainedservicetechnicianonly)replacethe
systemboard.
•S.51003[S.51003]AnuncorrectablememoryerrorwasdetectedinDIMMslot%onrank%.
Explanation:FatalMemoryErrorOccurred
Severity
Error
UserResponse
Completethefollowingsteps:
1.Ifthenodehasrecentlybeeninstalled,moved,serviced,orupgraded,verifythattheDIMM
isproperlyseatedandvisuallyverifythatthereisnoforeignmaterialinanyDIMMconnector
onthatmemorychannel.Ifeitheroftheseconditionsisfound,correctandretrywiththesame
DIMM.(Note:EventLogmaycontainarecent00580A4eventdenotingdetectedchangein
DIMMpopulationthatcouldberelatedtothisproblem.)
2.IfnoproblemisobservedontheDIMMconnectorsortheproblempersists,replacetheDIMM
identifiedbyLightPathand/oreventlogentry.
3.Ifproblemre-occursonthesameDIMMconnector,replacetheotherDIMMsonthesame
memorychannel.
4.CheckIBMSupportwebsiteforanapplicableservicebulletinorfirmwareupdatethatapplies
tothismemoryerror.
5.(Trainedservicetechnicianonly)Ifproblemre-occursonthesameDIMMconnector,inspect
connectorfordamage.Iffound,replacesystemboard.
6.(Trainedservicetechnicianonly)ReplaceaffectedProcessor.
7.(Trainedservicetechnicianonly)Replacesystemboard.
•S.51006[S.51006]Amemorymismatchhasbeendetected.Pleaseverifythatthememory
configurationisvalid.
Explanation:OneorMoreMismatchedDIMMsDetected
540LenovoSystemx3250M5InstallationandServiceGuide