4.Ifproblemre-occursonthesameDIMMconnector,swaptheotherDIMMsonthesamememory
channelacrosschannelsoneatatimetoadifferentmemorychannelorProcessor.(check
serviceinformationforthisproduct/Installguideforpopulationrequirementsforsparing/paring
modes).IfproblemfollowsamovedDIMMtoadifferentmemorychannel,replacethatDIMM.
5.CheckIBMSupportwebsiteforanapplicableservicebulletinorfirmwareupdatethatapplies
tothismemoryerror.
6.(Trainedservicetechnicianonly)IfproblemstayswiththeoriginalDIMMconnector,re-inspect
DIMMconnectorforforeignmaterialandremove,iffound.Ifconnectorisdamaged,replace
systemboard.
7.(Trainedservicetechnicianonly)RemoveaffectedProcessorandinspectProcessorsocketpins
fordamagedormis-alignedpins.Ifdamageisfound,orthisisanupgradeProcessor,replace
systemboard.IftherearemultipleProcessor’s,swapProcessor’stomoveaffectedProcesorto
anotherProcessorsocketandretry.IfproblemfollowstheaffectedProcessor(orthereisonly
oneProcessor),replacetheaffectedProcessor.
8.(Trainedservicetechnicianonly)Replacethesystemboard.
•S.68005[S.68005]AnerrorhasbeendetectedbythetheIIOcorelogiconBus%.TheGlobalFatal
ErrorStatusregistercontains%.TheGlobalNon-FatalErrorStatusregistercontains%.Please
checkerrorlogsforthepresenceofadditionaldownstreamdeviceerrordata.
Explanation:CriticalIOH-PCIError
Severity
Error
UserResponse
Completethefollowingsteps:
1.ChecklogforaseparateerrorforanassociatedPCIedeviceandservicethaterror.
2.CheckIBMSupportwebsiteforanapplicableservicebulletinorfirmwareupdateforthesystem
oradapterthatappliestothiserror.
3.(Trainedservicetechnicianonly)Replacethesystemboard.
•W.11004[W.11004]AprocessorwithinthesystemhasfailedtheBIST.
Explanation:ProcessorSelfTestFailureDetected
Severity
Warning
UserResponse
Completethefollowingsteps:
1.IftheProcessororfirmwarewasjustupdated,checkIBMSupportwebsiteforanapplicable
servicebulletinorfirmwareupdatethatappliestothisProcessorerror.
2.(Trainedservicetechnicianonly)IftherearemultipleProcessor’s,swapProcessor’stomove
affectedProcessortoanotherProcessorsocketandretry.Ifproblemfollowstheaffected
Processor,orthisisasingleProcessorsystem,replacetheProcessor.InspectProcessor
socketoneachProcessorremovalandreplacesystemboardfirstifdamagedormis-aligned
pinsarefound.
3.(Trainedservicetechnicianonly)Replacethesystemboard.
542LenovoSystemx3250M5InstallationandServiceGuide