•202-000-000:MemStrTestPassed
TestPassed.
Recoverable
No
Severity
Event
Serviceable
No
Automaticallynotifysupport
No
Relatedlinks
–IBMSupportwebsite
–LatestlevelofDSA
–LatestlevelofBMC/IMM
•202-801-000:MemStrTestAborted
Internalprogramerror.
Recoverable
No
Severity
Warning
Serviceable
Yes
Automaticallynotifysupport
No
UserResponse
Completethefollowingsteps:
1.Turnoffandrestartthesystem.
2.MakesurethattheDSADiagnosticcodeisatthelatestlevel.
3.Runthetestagain.
4.Ifthesystemhasstoppedresponding,turnoffandrestartthesystem.
5.Checkthesystemfirmwarelevelandupgradeifnecessary.
6.RunthememorydiagnostictoidentifythespecificfailingDIMM.
7.Ifthefailureremains,referto"Troubleshootingbysymptom"inthesystem"Installationand
ServiceGuide"forthenextcorrectiveaction.
Relatedlinks
–IBMSupportwebsite
–LatestlevelofDSA
–LatestlevelofBMC/IMM
AppendixC.DSAdiagnostictestresults671