Step2.RemovethePCIriser-cardassembly(see“RemovingthePCIriser-cardassembly”onpage163).
Step3.Removetheexpansion-slotfillerontheslotthatyouintendtouseandsaveforfutureuse.
Attention:PCIexpansion-slotfillersmustbeinstalledonallvacantslots.Thismaintainsthe
electronicemissionsstandardsoftheserverandensuresproperventilationofservercomponents.
Figure55.ServeRAIDSAS/SATAcontrollerinstallation
Step4.Touchthestatic-protectivepackagethatcontainsthenewServeRAIDSAS/SATAcontrollertoany
unpaintedsurfaceontheoutsideoftheserver;then,grasptheServeRAIDSAS/SATAcontroller
bythetopedgeoruppercornersoftheServeRAIDSAS/SATAcontrollerandremoveitfromthe
package.
Step5.Takethesignalcablethatisattachedtothedrivebackplateassembly/backplaneandconnectitto
theServeRAIDSAS/SATAcontroller.