Table 26. System-board-assembly LEDs description (continued)
LED
Description
Action
4. If the problem still remains, contact Lenovo
Support.
5 FPGA heartbeat
LED (green)
The FPGA heartbeat LED helps
you identify the FPGA status.
Blinking (1Hz) : FPGA is
working normally.
On or off: FPGA is not
working.
If the FPGA heartbeat LED is always off or always on, do
the following:
1. Replace the processor board.
2. If the problem remains, contact Lenovo Support.
6 DIMM error LED
(yellow)
LED on: an error has occurred to
the DIMM the LED represents.
For more information, see
“Memory problems” on page
206
.
LEDs on the firmware and RoT security module
The following illustrations show the light-emitting diodes (LEDs) on the ThinkSystem V3 Firmware and Root
of Trust Security Module (firmware and RoT security module).
Figure 131. LEDs on the firmware and RoT security module
1 AP0 LED (Green) 2 AP1 LED (Green) 3 Fatal Error LED (Amber)
Table 27. LEDs description
Scenario AP0 LED AP1 LED
Fatal
Error
LED
FPGA
heart-
beat
LED
note
XCC
heart-
beat
LED
note
Actions
RoT security module
fatal firmware failure
Off Off On N/A N/A Replace the firmware and RoT
security module.
Blink N/A On N/A N/A Replace the firmware and RoT
security module.
Blink
N/A On On N/A Replace the firmware and RoT
security module.