•  The operating system supports the USB device.
2.  Make sure that the USB configuration options are set correctly in system setup.
Restart the server and press the key according to the on-screen instructions to display the LXPM system 
setup interface. ((For more information, see the “Startup” section in the LXPM documentation 
compatible with your server at 
https://sysmgt.lenovofiles.com/help/topic/lxpm_frontend/lxpm_product_ 
page.html
.)) Then, click System Settings ➙ Devices and I/O Ports ➙ USB Configuration.
3.  If you are using a USB hub, disconnect the USB device from the hub and connect it directly to the 
server.
4.  If the USB device is still not working, try to use a different USB device, or try to connect the USB device 
that is being tested to another working USB connector.
5.  If the USB device works well on another USB connector, the original USB connector may have a 
problem. 
•  If the USB connector is on the front of the server:
a.  Remove and reconnect the USB cable. Ensure that the USB cable is correctly connected to the 
system board (system board assembly). See 
Chapter 6 “Internal cable routing” on page 157
b.  Replace the front panel or front I/O module.
•  If the USB connector is at the rear of the server: 
a.  (Trained technician only) Replace the system I/O board.
Memory problems
See this section to resolve issues related to memory.
Common memory problems
• 
“Displayed system memory is less than installed physical memory” on page 206
•  “Invalid memory population detected” on page 207
•  “DIMM PFA issue” on page 207
Displayed system memory is less than installed physical memory
Complete the following procedure to solve the problem.
Note: Each time you install or remove a memory module, you must disconnect the server from the power 
source.
1.  See 
“Memory module installation rules and order” on page 39 to make sure that the present memory 
module population sequence is supported and you have installed the correct type of memory module.
2.  Check whether any DIMM error LED is lit on the processor board and whether any memory module is 
not displayed in Setup Utility. If yes, check the customer/L1 actions by following the error event 
triggered in XCC or UEFI.
3.  If the problem persists, replace the failing memory module with one that functions well. 
•  If the new memory module still functions well, it indicates that the original memory module is 
damaged. In this case, replace the memory module with a good one.
•  If the new memory module cannot function well, it indicates that the memory slot is damaged. In this 
case, replace the processor board (trained technician only).
•  There are few cases in which the memory error is relative to processors. Replace the affected 
processors if the above actions does not help on customer’s situation (trained technician only).
4.  Run the memory module diagnostics. When you start a server and press the key according to the on- 
screen instructions, the Lenovo XClarity Provisioning Manager interface is displayed by default. From 