• If the server is installed in a rack, slide the server out on its rack slide rails to gain access to the top cover,
or remove the server from the rack. See
“Remove the server from rack” on page 45.
• If you are not installing a replacement memory module to the same slot, make sure you have memory
module filler available.
• Memory modules are sensitive to static discharge and require special handling. Refer to the standard
guidelines for
“Handling static-sensitive devices” on page 38.
– Always wear an electrostatic-discharge strap when removing or installing memory modules.
Electrostatic-discharge gloves can also be used.
– Never hold two or more memory modules together so that they do not touch each other. Do not stack
memory modules directly on top of each other during storage.
– Never touch the gold memory module connector contacts or allow these contacts to touch the outside
of the memory module connector housing.
– Handle memory modules with care: never bend, twist, or drop a memory module.
– Do not use any metal tools (such as jigs or clamps) to handle the memory modules, because the rigid
metals may damage the memory modules.
– Do not insert memory modules while holding packages or passive components, which can cause
package cracks or detachment of passive components by the high insertion force.
Important: Remove or install memory modules for one processor at a time.
Watch the procedure
A video of this procedure is available at YouTube:
https://www.youtube.com/playlist?list=PLYV5R7hVcs-
CTkyVDu-5Lhy1r9G-4PQGl
.
Procedure
Step 1. Power off the server and disconnect all power cords.
Step 2. Remove the top cover. See
“Remove the top cover” on page 150.
Chapter 5. Hardware replacement procedures 79