the digital display, BARRELS in this example, and the display will then display the volume
information. The display will switch back to the default units automatically after about 30
seconds, or it may be switched back by pressing the ALTERNATE UNITS button again.
To acknowledge alarm and fault conditions, press the ACK button. If an alarm light is
flashing to indicate a new alarm condition, the light will stop flashing and remain lit after the
ACK button has been pressed.
The machine is configured to sample the sense line regularly. It can be configured to
automatically sample the sense line when a change in depth is detected as well. To
conserve air it might be desired to have the machine sample infrequently, and not
automatically sample on a change of depth. You can manually trigger a sample any time by
pressing the UP or DOWN button while the machine is in normal operation. The display will
show the text message WAIT until the new sample operation is complete. Then the machine
will display the new reading.