Page 59
©2013 Technical Marine Service, Inc. LC-100 V2.97
6. Press MENU to select this function. An asterisk (*) will appear to the right of the display
indicating the function has been selected.
7. Press ENTER. SAVING will appear briefly on the display. The unit will display DEPTH.
8. Press the UP or DOWN keys to scroll through the menu selections.
9. Press MENU key to select the gauge output you want.
10. Press ENTER. SAVING will appear briefly on the display and the display will shift to
GAUGE.
11. Press ESCAPE to return to normal operation.
Specific Gravity Gauge Output Setup
If the analog output is configured as a specific gravity gauge output there is an additional
consideration. The span of the 4 – 20 mA signal must be set up. This requires setting the
minimum specific gravity value, which corresponds to the 4 mA, and setting the maximum
specific gravity value, which corresponds to the 20 mA signal.
1. Enter Program Mode by pressing the MENU key.
2. At SYSTEM press the UP or DOWN keys to scroll to OUTPUTS.
3. Press ENTER. The unit will display LIGHTS.
4. Press the DOWN key until unit displays ANALOG OUTPUT.
5. Press ENTER. The unit will display GAUGE.
6. Press MENU to select this function. An asterisk (*) will appear to the right of the display
indicating the function has been selected.
7. Press ENTER. SAVING will appear briefly on the display. The unit will display DEPTH.
8. Press the UP or DOWN keys to scroll through the menu selections until the display shows
SPECIFIC GRAVITY.
9. Press MENU key to select this option.
10. Press ENTER. SAVING will appear briefly on the display and the display will shift to MIN
S G.
11. Press ENTER. The unit will display 0.0.