Page 51
©2013 Technical Marine Service, Inc. LC-100 V2.97
15. Press UP or DOWN to scroll to the total tank volume at point #9 using the Volume or
Weight Units selected in Basic Programming.
16. Press ENTER. SAVING will appear briefly on the display and the display will shift to D8.
17. Repeat steps 11 through 16 for Depth and Volume/Weight levels 8 through 1. After all
levels are programmed, the unit will display BUBBLER TO BOTTOM.
18. At BUBBLER TO BOTTOM press ESCAPE to return to normal operation or press ENTER
to program the Bubbler to Bottom if not done already.
Password
Access to the LevelCom 100 program can be restricted by the use of a password. As
previously discussed, the LevelCom 100 can be programmed with a user defined Hot Menu
which will provide immediate, non-password-protected access to some commonly used
features.
If a password has been set up the LevelCom 100 will display ENTER PASSWORD whenever
an attempt is made to enter into the program mode. Once the password has been
programmed and the program exited, the password must be used. The password is entered
using the same keystrokes as described below in Programming a Password steps 4 - 8.
Programming a Password
1. Press MENU. The unit will display SYSTEM.
2. Press UP or DOWN to scroll to NEW PASSWORD.
3. Press ENTER. The unit will display a flashing underline as a cursor.
Note: The LevelCom 100 password selection consists of the letters A-Z. A password of 1 to
9 characters can be set up.
4. Press UP or DOWN to scroll to the first character.
5. Simultaneously press MENU and the UP key to shift to the next character.
6. Press UP or DOWN to scroll to the second character.
7. Repeat steps five and six until your password is displayed.
8. Press ENTER. SAVING will appear briefly on the display and the display will return to
NEW PASSWORD indicating your password has been saved.