Page 37
©2013 Technical Marine Service, Inc. LC-100 V2.97
Press UP. The unit will display MEMORY.
Press ENTER. The unit will display WRITE OVER BACKUP.
Press UP. The unit will display ERASE ALL MEMORY.
Press ENTER. The unit will display SURE?
Press ENTER. The unit will reset and display SYSTEM.
At SYSTEM continue with programming or press ESCAPE to return to operation with factory
set defaults.
Display Setup
Note: All descriptions of configuring the display assume that the LevelCom 100 is
being configured for the first time after the memory has been erased. If the unit
already has an existing configuration the initial numbers seen when entering the
Maximum Depth and the Bubbler to Bottom values will be different than described in
this procedure.
1. At SYSTEM press ENTER. The unit will display DISPLAY SETUP
2. Press ENTER. The unit will display DEPTH UNITS.
3. Press ENTER. The unit will display INCHES*.
4. Press UP or DOWN to scroll to the depth unit of measure you have chosen for use.
5. Press MENU to select the choice. An asterisk (*) will appear to the right of the display
indicating the item has been selected. If depth is to be displayed in ullage proceed to the
next step, if not then proceed to step 7.
6. Press UP or DOWN to scroll to ULLAGE. Press MENU if you wish depth to be displayed
in ullage. An asterisk (*) will appear to the right of the display indicating the item has
been selected.
7. Press ENTER to save the selection(s). SAVING will appear briefly on the display and the
display will return to DEPTH UNITS indicating the selection has been recorded.
8. Press DOWN. The unit will display VOLUME UNITS.
9. Press ENTER. The unit will display NOT USED*.
10. Press UP or DOWN to scroll to the volume unit of measure you have chosen for use.