EasyManua.ls Logo

Levelcom 100 - Programming a Tank Table

Default Icon
101 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Page 50
©2013 Technical Marine Service, Inc. LC-100 V2.97
The Tank Table can consist of from one to 10 level entries. Use as many levels as required
to achieve the best accuracy. Levels must be entered from the top of the tank working
down. TMS recommends the user plot a chart, which graphs the depth to volume/weight
curve. This provides the best means to determine the points of greatest depth to
volume/weight change and the optimum arrangement for the Tank Table (Figure 21).
Transfer this data to the Programming Worksheet for the tank and proceed with the
programming instructions below. If you require assistance in establishing the Tank Table
please call TMS.
Programming a Tank Table
1. Enter Program Mode by pressing the MENU key.
2. At SYSTEM press ENTER. The unit will display DISPLAY SETUP.
3. Press ENTER. The unit will display DEPTH UNITS.
4. Press UP. The unit will display TANK TABLE.
5. Press ENTER. The unit will display MAX DEPTH.
6. Press ENTER. The unit will display the parameter that was assigned during Basic
Programming. Confirm that this value is correct and modify if required.
7. Press ENTER. The unit will display MAX VOLUME or MAX WEIGHT.
8. Press ENTER. The unit will display either 0 or the parameter that was assigned during
Basic Programming.
9. If 0 press UP or DOWN to scroll to the maximum capacity of the tank. If a parameter has
already been established, confirm that the value is correct and proceed to the following
step.
10. Press ENTER to save the selection. If a new value was assigned SAVING will appear
briefly on the display and the display will shift to D9.
11. Press ENTER. The unit will display 0.0.
12. Press UP or DOWN to scroll to the depth at point D9 using the Depth Units selected in
Basic Programming.
13. Press ENTER to save the selection. SAVING will appear briefly on the display and the
display will shift to V9 or W9.
14. Press ENTER. The unit will display 0.0.

Table of Contents