Page 52
©2013 Technical Marine Service, Inc. LC-100 V2.97
Note: This password will be required to enter into the configuration program. TMS
recommends you set up a Hot Menu to access those parameters you would like accessible
but not password protected. If the password is lost please call TMS for assistance.
Hot Menu
The LevelCom 100 is programmed with a Hot Menu feature. This allows the user to set up
certain parameters and functions into a menu that is instantly accessible simply by pressing
the MENU key. This feature is especially helpful if the user has set up password protection.
Once the Hot Menu has been programmed the LevelCom 100 will display HOT MENU when
the MENU key is pressed. The parameters set up in the Hot Menu are accessible by
scrolling with the UP or DOWN keys.
Programming Hot Menu
1. Enter Program Mode by pressing the MENU key.
2. At SYSTEM press the UP or DOWN keys to scroll to HOT MENU.
3. Press ENTER. The unit will display the first alarm point activated, HI for example. If no
alarms are configured the display will show SPEC GRAV.
4. Press the UP or DOWN keys to scroll through the functions and parameters available for
the Hot Menu.
5. Select those functions/parameters you wish displayed in the hot menu by pressing the
MENU key. An asterisk (*) will appear to the right of the display indicating the item has
been selected.
6. After selecting the Hot Menu items press ENTER. SAVING will appear briefly on the
display and the display will return to HOT MENU indicating the selections have been
recorded.
7. Press ESCAPE to return to normal operation.
LevelCom Outputs
The LevelCom 100 has a number of output devices available. The alarm and fault lights in
the front panel are always available. In addition there are optional relays that can be
configured to function as alarm, or control outputs, an optional horn to give local alarm
indication, an optional 4-20 mA output that can be used as a gauge, or control output. The
LevelCom 100 can also be equipped with an optional digital communication interface that
allows it to communicate with up to four remotely mounted LevelCom 101 Repeaters.