2. Press ENTER. The unit will display COMM SETUP.
3. Press ENTER. The unit will display NETWORK ADDRESS.
4. Press DOWN. The unit will display BAUD RATE.
5. Press ENTER. This unit will display 1200.
6. Press UP or DOWN to scroll to the required baud rate. The possibilities are 1200, 2400,
4800, 9600, and 19200.
7. With the desired baud rate showing on the display, press MENU to select. An asterisk
will show on the right side of the character display
8. Press ENTER to save the selection. SAVING will appear briefly on the display. The
display will return to BAUD RATE.
You also need to verify the parity setting of the device you are connecting the LevelCom 100
to. The most common setting is N-8-1, no parity, 8 bits per byte, one stop bit. This will be
the normal default for interfacing to desktop computers.
The other settings are often encountered when interfacing to PLCs or data scanners. Some
of these devices will not support N-8-1 parity settings. If no parity is used they may operate
with the parity bit always set, this will be N-8-2 parity. Alternately they may only support even
or odd parity settings. To determine the required setting see the manual for the device you
are connecting the LevelCom 100 to.
1. At SYSTEM press UP, the unit will display UTILITIES.
2. Press ENTER. The unit will display COMM SETUP.
3. Press ENTER. The unit will display NETWORK ADDRESS.
4. Press DOWN twice. The unit will display PARITY.
5. Press ENTER. The unit will display N-8-1.
6. Press UP or DOWN to scroll to the required parity. The possibilities are N-8-1, N-8-2,
EVEN (E-8-1), and ODD (O-8-1).
7. With the desired parity setting showing on the display, press MENU to select. An asterisk
will show on the right side of the character display
8. Press ENTER to save the selection. SAVING will appear briefly on the display. The
display will return to PARITY.