Page 86
©2013 Technical Marine Service, Inc. LC-100 V2.97
operator. They are automatically detected by the LevelCom 100 when it first starts operation,
and the devices detected are shown here for troubleshooting. There are some options that
can be changed here though; Automatic Specific Gravity, Differential Pressure, Passive
Gauge, and Sample Timing.
It is very important to understand the function of the configurable parameters before
changing them. If these are set up incorrectly the machine will not function correctly.
Operators should contact TMS before changing any of these settings. It is important to
understand what each option does. The following section describes all options under the
HARDWARE.
Accessing the Hardware menu
First you must set up temporary a password in the LevelCom 100 if there isn’t already a
password programmed (A for example). If there is already a password programmed into the
machine you don’t have to change it. You need a password in the machine so that you will
be asked to enter a password before entering the operator interface.
Now enter the configuration menus, when the machine asks for you to enter the password,
use the special password SETXYZ.
After entering the password the machine will display SYSTEM. Press UP and the machine
will display UTILITIES.
Press ENTER, the machine will display COMM SETUP. Press UP and the machine will
display HARDWARE. This is the special hardware configuration menu. You must enter the
configuration interface using the password SETXYZ to have access to this menu. Normally it
isn’t available in the UTILITIES menu.
Press ENTER, the machine will display 15 PSI.
The menu begins with a list of possible pressure sensor types and other optional hardware
installed. You will see an asterisk * in the rightmost character in the interface identifying the
options installed. If an option can be activated by the operator, the MENU key is pressed to
activate or de-activate that item. In this case the asterisk indicates that the item is active.
The list with descriptions of each item is as follows. You will use the DOWN arrow button to
scroll through this list:
15 PSI: A 15 psi sensor is installed. Not modifiable.
30 PSI: A 30 psi sensor is installed. Not modifiable.
100 PSI: A 100 psi sensor installed. Not modifiable.