To clear the event log:
1 From the Diagnostics menu, navigate to:
Event Log > Clear Log
2 Choose any of the following:
• Yes—To clear the Event log
• No—To exit the Clear log menu
Scanner tests
• “ASIC test” on page 169
• “Motor tests” on page 169
• “Feed test” on page 170
• “Sensor tests” on page 170
• “Scanner calibration reset” on page 173
• “ADF magnification” on page 173
ASIC test
This setting initiates a scan of the scanner ASIC’s memory.
To perform this test, do the following:
1 Navigate to Scanner Tests > ACIS Tests.
2 Select ACIS Tests.
3 The test executes. While this test executes, the screen displays ASIC Test Running.... If the scanner ASIC
passed the test, then the panel posts ASIC Test Passed. Rebooting.... If the scanner ASIC failed the
test, then the panel posts ASIC Test Failed. Rebooting....
Motor tests
The motor tests allow you to test the functionality of the motors in the ADF unit.
ADF pick
When Motor On is selected, the device runs the pick motor continuously for five seconds and then automatically stops
the motor.
To perform this test, do the following:
1 Navigate to Scanner Tests >Motor Tests.
2 Select ADF pick.
The test will run if it is working properly.
Flatbed scanner motor
When Motor On is selected, the device moves the flatbed scanner along the entire flatbed scanner path (that is, to the
far wall and back to the Home position) and then automatically stops at the Home position.
7015
Service menus
169