8 Remove the E-clip (E), and then remove the MPF sector gear (F).
EF
Reverse solenoid removal
1 Remove the right cover. See “Right cover removal” on page 226.
2 Remove the left cover. See “Left cover removal” on page 209.
3 Remove the rear door and cover. See “Rear exit door removal” on page 301 and “Rear cover removal” on page
302.
4 Remove the scanner assembly. See “Scanner assembly removal” on page 319.
5 Remove the top cover. See “Top cover assembly removal” on page 307.
6 Remove the cooling fan. See Cooling fan removal” on page 230.
7 Disconnect cable JDSOL1 from the controller board.