142.xx—Cyan cartridge motor error service check
4
Remove the system board cage. See
“System board cage with board removal”
on page 4-157.
Check the cable connected to the black
cartridge motor.
Is the cable connected properly?
Go to step 5. Reseat the cable.
5
Replace the EP drive assembly. See “EP
drive assembly removal” on page 4-54.
Does the error reoccur?
Replace the system board.
See “System board
removal” on page 4-150.
Problem solved.
Step Questions / actions Yes No
1 Turn the printer off, open the system board
shield, and remove the RIP card shield.
Check the cable in the connector JCM1 for
proper connection to the system board.
Is the cable properly connected?
Go to step 2. Reseat the cable.
2
Check the cable for damage.
Is the cable damaged?
Replace the BLDC C&M
cable. See EP drive
assembly removal” on
page 4-54.
Go to step 3.
Step Questions / actions Yes No