Repair information 4-235
7562
Go Back
Previous
Next
Scanner reference LED removal
See “Flatbed scanner” on page 7-19 for the part number.
1. Remove the scanner platen glass cover. See “Scanner platen glass cover removal” on page 4-234.
2. Disconnect the cable from the sensor.
3. Remove the screw (A) to remove the sensor.
Scanner reference LED sensor cable removal
See “Flatbed scanner” on page 7-19 for the part number.
1. Remove the scanner platen glass cover. See “Scanner platen glass cover removal” on page 4-234.
2. Disconnect the cable (A) from the scanner interface card and from the sensor.
3. Remove the cable from the frame.
Note: Observe the cable routing for reinstallation.