Diagnostic information 2-177
7562
Go Back
Previous
Next
4
Remove the staging deflector assembly, and
check the sensor cable connection. See
“Staging deflector assembly removal” on
page 4-138.
A—Input sensor
B—S1 sensor
C—Narrow media sensor
D—Near narrow media sensor
Is the cable properly connected?
Go to step 5. Reseat the cable.
5
Replace the sensor. Sensor (input, S1,
narrow media, near narrow media)
removal” on page 4-137
Does the error reoccur?
Replace the system board.
See “System board
removal” on page 4-150.
Problem solved.