Diagnostic information 2-89
7510
291.00 Sensor (ADF registration) static jam
291.01 Sensor (ADF inverter) lag jam (inverting)
Step Check Yes No
1 Check the media path.
Is the media path free of media or media fragments?
Go to step 2. Remove any
media or media
fragments.
2
Check the sensor (ADF registration) for proper operation.
1. Enter the Diagnostics Menu.
2. Touch SCANNER TESTS.
3. Touch Sensor Tests.
4. Touch ADF registration.
Does the display on the operator panel, change every time the
sensing area of the above sensor is interrupted or blocked?
Go to step 4. Go to step 3.
3
Check the sensor (ADF registration) for proper connection.
Is the above component properly connected?
Replace the
sensor (ADF
registration).
Go to “Sensor
(ADF
registration)
removal” on
page 4-149.
Replace the
connection.
4
Place an undamaged document in the ADF, and perform a ADF
test.
Does the error remain?
Replace the
ADF controller
card assembly.
Go to “ADF
controller card
assembly
removal” on
page 4-138.
Go to step 5.
Problem solved.
5
Place an undamaged document in the ADF, and perform a ADF
test.
Does the error remain?
Replace the
RIP card
assembly.
Go to “RIP
card assembly
removal” on
page 4-73.
Problem solved.
Step Check Yes No
1 Check the original document condition.
Is the original document free of paper clips and staples as
well as damage such as creases, tears, holes or excessive
wear?
Go to step 2. Remove damaged
original document
and replace with a
new undamaged
original document.
Perform a ADF
test. If the problem
remains, go to
step 2.