4-124 Service Manual
7510
Sensor (scanner HP) removal
1. Remove the scanner top rear cover. See “Scanner top rear cover removal” on page 4-118.
2. Remove the large platen glass. See “Large platen glass removal” on page 4-117.
3. Gently move the scanner carriage (A) rightward to provide access to the sensor (scanner HP) (B).
4. Release the hooks securing the sensor (scanner HP) (B) to the scanner unit assembly.
5. Disconnect the connector from the sensor (scanner HP) (B).
6. Remove the sensor (scanner HP) (B).
B
Connectors
Connector
Connector
C
Connector
B
A